Chave Seccionadora 11kv

China 
                                 Chave Seccionadora 11kv                              fabricação e fornecedor

Chave Seccionadora 11kv image

Get Latest Price Request a quote

Informação Básica

N ° de Modelo.
IST-12/400

Tipo
Alta Voltagem

Estrutura
Disconnector com Três Colunas

Instalação
Alta Voltagem Exterior

Operação
Manual

Modo de aterramento
Aterramento

Modo de Movimento
Horizontal Rotary Tipo

Número de polos
Três Pólos

Encalhe
Único fundamento

Série
Três

Corrida
Vire o Horizontal

Estrutura de Operação
Manual

Informação Adicional

Marca Registrada
OEI Power

Embalagem
Cartons Pallets Wooden Case

Padrão
IEC62271-102

Origem
China Nanyang

Código HS
8535309000

Capacidade de Produção
7000

Descrição de Produto

MV exterior Off-Load chave seccionadora
(Alternando seccionador atual)

ESPECIFICAÇÃO TÉCNICA

    	

  1. 		Escopo
    		Tipo IST off-carga switchs são adequados para utilização em zona tropical, com a temperatura ambiente máxima de aproximadamente 40 graus centígrados e uma temperatura média de cerca de 28 graus centígrados, com elevada humidade e precipitação pesada. A altitude operacional preferido é de até 1800 m acima do nível do mar.
    		
    		Sistema Elétrico
    		Tipo IST off-load interruptor isolador são projetados para operação contínua em um 3-fase 3 fios 11, 15,22,24,27and 33,36kV, 50 / 60Hz sistema de distribuição com o ponto-estrela do transformador ponto-fonte ligada à terra através de uma bobina de supressão de arco ou aterramento do resistor.
    		
    		Standards
    		Tipo IST off-load interruptor isolador são respeitadas normas pertinentes das seguintes normas, juntamente com todas as alterações em curso;
    		 
    IEC62271-102: 2003: de alta tensão seccionadores de corrente alternada e chaves de aterramento
    		      
    IEC60129: 1984: Alternando seccionadores e comutadores atuais terra
    		      
    IEC 60265-1: 1998: comutadores de alta tensão – Parte 1: Switches para Classificado
    		                       
    tensão acima de 1kV e menos de 52kV
    		
    		      
    IEC 60694: 1996: As especificações comuns para comutadores de alta tensão e
    		                       
    normas controlgear
    		
    		      
    IEC 60815: 1986: Guia para a seleção de isoladores em relação a
    		                        
    condições poluídas
    		
    		      
    BS EN ISO 1461: dip revestimentos galvanizado a quente de ferro fabricada e
    		                                
    Especificações artigos- aço e métodos de ensaio
    		4.0 Construção
    		4.1 Geral
    		4.1.1 Tipo IST off-load switchs isoladores são a montagem vertical / horizontal
    		Tipo para montagem em uma estrutura única ou H-pólo para cima
    		linhas ou alimentadores das secções energizado.
    		         

    		4.1.2 Tipo IST switchs off-load isoladores são compatíveis e pronto para
    		instalação em postes de aço tubular e postes de concreto fiadas.
    		 
    4.1.3 O projeto é de um ar isolados "balanço isolante"
    		digitar com as duas mensagens de isoladores fixa e uma móvel
    		isolador de pós por fase.
    		        

    		4.1.4 Todas as peças de aço e ferro será galvanizado para proteger da corrosão
    		por BS EN ISO 1461
    		 
    		            
    4.1.5 Tipo IST off-load switchs isoladores são equipados com um único mecanismo de funcionamento e barras de acoplamento adequados que vão operar todas as fases simultaneamente e que as operações independentes de cada
    		                       
    pólo, independentemente do estado dos outros pólos, não é permitido

	 
	ESPECIFICAÇÕES
	 

	 

	

		

			

			

			

			

			

		

		

			

			

			

		

		

			

			

			

			

			

		

		

			

			

			

		

		

			

			

			

			

		

		

			

			

			

		

		

			

			

			

			

		

		

			

			

			

			

		

		

			

			

			

		

		

			

			

			

			

		

		

			

			

		

	

				
				 
				i. Rated Voltage 				12kV 				24KV 				36KV
				
				 
				ii. Rated Continuous Current Carrying
				Capacity
				Not Less Than 400A Up to 630A
				
				 
				iii. Rated Short-Time Withstand Current (rms) 				12KV 				24KV 				36KV
				
				 
				
				>=20KA / 3 sec
				
				>=25KA/ 3 sec
				iv. Lightning Impulse Withstand
				Voltage (peak)
				-To earth and between poles
				min
				max
				12KV 				24KV 				36KV
				
				60KV
				75KV
				
				95KV
				125KV
				
				145KV
				170KV
				-Across the isolating distance min
				max
				
				70KV
				85KV
				
				110KV
				145KV
				
				165KV
				195KV
				
				v. Power Frequency Withstand Voltage(r.m.s)
				-To earth and between poles
				12KV 				24KV 				36KV
				
				28KV
				
				50KV
				
				70KV
				-Across the isolating distance 				32KV 				60KV 				80KV
				vi. Average Ambient Temperature
				(Maximum)
				
				28ºC (40ºC)

	 

	

		

			

			

		

		

			

			

		

		

			

			

			

			

		

		

			

			

			

		

		

			

			

			

		

	

				i. Humidity Range 				0-100%
				ii. Preferred Altitude Requirement 				Up to 1,800m
				iii. Insulators
				Total Creepage Distance (mm)
				Min
				Max
				12KV 				24KV 				36KV
				192 				384 				576
				465 				600 				900

1.1 Operation
1.1.1 Type IST off-load isolator switchs are designed to provide a smooth,
Lightweight action requiring minimum maintenance.

1.1.2 The complete operating mechanism parts are sufficiently
Insolated from live parts, and grounded for the safety of the operator.
The operating mechanism shall be of robust,adjustable design with padlock facility in either the "OPEN" and "CLOSE" positions.

1.1.3 The complete operating mechanism are comed complete with an
Operating handle and shall be designed for steady manual operation
From ground level.

1.1.4 The insulation for the operating mechanism handle are sufficient
For the safety of the operations and preferably incorporated with an
Anti-slip grip.

1.1.5 The vertical drive rod is suitable length and shall be provided
With facilities to extend or reduce the length. Suitable couplings and operating rod guides shall be supplied with each operating mechanism.

1.1.6 If possible, it can be designed that the operating mechanism handle
use for both LEFT and RIGHT hand operations. The direction
Of the operations are clearly indicated on the operating mechanism.

1.1.7 Type IST off-load isolator switchs are designed to prevent unwanted
Operations such that:

1.1.7.1 Type IST off-load isolator switchs OPEN or CLOSE position are
remain constant despite:

a. forces arising from gravity,vibration or reasonable shock
b. accidental touching of the connecting rods or operating
devices
c. electromagnetic forces

1.1.1.1 Type IST off-load isolator switchs have provisions to prevent
Unauthorized operations
1.1.2 The OPEN or CLOSE position of the Off-Load Isolator Switch are
Easy to see from ground level by:
1.1.2.1 having a visible gap or isolating distance
1.1.2.2 having a reliable indicating device of the position of the movable
contacts.

1.1.3 Type IST off-load isolator switchs have adequate mechanical
Strength on its terminal to withstand the total forces,including
Wind loading and electromagnetic forces, related to its application
And rating,without reduction of its reliability or current carrying once
It has been installed vertically on single or H-pole structure.

1.2 Grounding
An earth terminal stud with a minimum size M12 shall be provided for the
Grounding of the operating mechanism, the terminal is marked with the
"earth" symbol.

1.3 Insulator
The materials for the insulator is silicon rubber or Porcelain, Other composite material Such as EPDM and porcelain can be Choosed.

1.4 Stationary and Moving Contacts

1.4.1 The main current carrying contacts are designed to ensure good
Electrical conductivity and to minimize pitting during operation. The
Design shall also ensure that a constant pressure is applied uniformly
Between the moving and fixed contacts.

6.2 Type Test

6.2.1 Type IST off-load isolator switchs had passed the type tests in accordance to IEC62271-102, IEC 60265-1 (or equivalent), IEC 60694 (or equivalent) and other related amendments,

a. Dielectric test per Clause IEC 62271-102-2001 Ed 1.0 2001-12
b. Measurement of resistance of the main circuit as per Clause IEC 62271-1-2007
c. Temperature rise tests as per Clause IEC 62271-102-2001
d. Short-time withstand current and peak withstand current tests as per Clause IEC 62271-102
e. Mechanical operation tests as per Clause 6.102 IEC 60265-1
Type Tests for items a,b,c&e as mentioned in Clause 7.2.1 above are conducted at an accredited independent laboratory and
6.2.2 Type Tests for items d as mentioned in Clause 7.2.1 above is conducted at an STL or STLA laboratory CPRI INDIA
6.3 Routine Tests

Routine tests are carried out by the manufacturer on all products in the finished state or, where appropriate, during the manufacturing processes. The routine test that are made on Type IST off-load isolator switchs are:-

i. Dielectric test per Clause IEC 62271-102
ii. Measurement of resistance of the main circuit IEC 62271-102
iii. Design and visual check as per IEC 62271-102
iv. Mechanical operation tests per Clause IEC 62271-102

7.0 Quality Control

We are arleady set up and implement a good quality management system. This system shall be inspect/audited by The customer appointed Quality Audit Agent before the commencement of any new contract and subsequently at agreed regular interval to ascertain the proper implementation of the quality management system.

Nós somos China Chave Seccionadora 11kv fabricação e fornecedor,Você pode obter mais detalhes com e-mail, você obterá preço barato ou preço de fábrica.

Get Latest Price Request a quote

Popular Chave Seccionadora 11kv Produtos

  • No related articles
  • Popular Comutador Desligar Produtos

    Supressor de surtos de tensão 11kv

    Alta voltagem do interruptor desligar 21kv

    Interruptor de desligar 1000A 33kv

    Piscina 3 Fase 30kv 33kv 35kv 36kv Desligar / Seccionador Modelo Gw4

    Isolador da bobina do VE 76 X 65

    Disco de alta qualidade Isolador de cerâmica de Suspensão

    Popular Desligar Produtos

    Isolador de Tensão Alta -/Massa mudar 12kv 400A

    33kv/69kv trifásicas de alta tensão exterior desligar o interruptor isolador

    A GW4 Piscina AC Seccionador

    Interruptor de alta tensão - Isolar 15kv 400A

    Alta Tensão do interruptor de isolar 11kv

    Interruptor de alta tensão - Isolar 12kv 630A

    Popular jgtrade1 Produtos

    Piercingconnector isolados

    Recorte de fusíveis de drop out 125kv

    33kv 5A Expulsão do Elo Fusível

    PE/ABS

    O fusível do cilindro cai fusíveis 18kv 200A

    Isolador, estirpe 15kv 1/2"

    Tags: , , ,

    SERVIÇO RÁPIDO E CONFIÁVEL PARA SEU PROJETO

    Contate nossos especialistas treinados hoje para encontrar sua solução de energia perfeita.

    FAÇA UMA PERGUNTA